SimplyLive

Release SimplyLive Version 2.1

Package Highlights

This package delivers several key features and the official release of certain software packages

Feature

Description

Clip Companion - Generally Available

Official release of the new browser-based web app Clip Companion for use with ViBox. A second screen that allows users to manage clips and playlists in the system.

Clip Companion is a web application designed around traditional replay workflows providing even greater asset management over internal system assets in a familiar interface.

SimplyLive Production Suite Flex Backend/Venue Gateway Mode Selector - Generally Available

The new mode selector is an application available for SimplyLive Production Suite Flex servers, allowing customers to run the server hardware in either - Backend or Venue Gateway modes. Providing even more flexibility to the solution, customers can run their “Flex” system as a Replay, Review, Video Server or Live Production system or run it as a Venue Gateway for remote contribution encoding workflows.

Venue Gateway Channel Density

The flex licenses for Venue Gateway will enable the Venue Gateway functionality only, with the number of supported inputs matching the channels included in the Backend license installed on the SimplyLive server.

It is mandatory that the Backend license is also installed on a system, and the Venue Gateway cannot be installed on a Flex server that does not already have Backend software installed.

SKAARHOJ Switcher Panel Integration

Using a new API providing a sub-set of Keyboard shortcut commands for ViBox via a gRPC endpoint we have partnered with SKAARHOJ to offer hardware-based switcher panels, designed around an All-in-One Live User workflow.

Customers can now use a hardware panel, such as the SKAARHOJ MasterKey48 switcher panel, to control the ViBox software and build a Switcher Panel for ViBox Production. Ideal for any operator running an All-in-One production that wants to use a hardware panel over our typical touch-screen workflow.

Increased the number General Purpose Outputs assignable to RTDs

We have increased the number of GPOs that can be triggered by RTDs from 8 to 16 (for any machines with 256 GB or more of RAM). This allows triggering external 3rd party devices, such as SCTE inserters, Downstream GFX engines or other Signal Processing devices when an RTD has been used in a production. Enabling even more complex workflows when using the ViBox Production software with one or more operators.

Enhancements to ViBox

The following enhancements have been made to ViBox, increasing the number of workflows that can be supported and responding to requests that make life as a single operator running a high-profile live production even easier.

  • Four new Keyboard shortcuts for Aux Channels

  • Name the Manual Transitions buttons with custom labels

  • New Macro parameter for pre-loading clips & playlists, now load to PGM in addition to PRV

  • New Macro parameter for +/- frame seek, now not only for reply but also available for PGM and PRV as well

  • New Macro to Mark the Out point for Replay, PGM or PRV

  • Cut playlist item functionality is not available in the UI (previously only available using an RCU)

  • Cut playlist item shortcut available in the ShuttleXpress

Automatic Ingest for Graphics & RTDs

It is now possible to use watch folders to automatically ingest RTD and Graphics assets into the SimplyLive Server, following the same logic applied to the automatic ingest for clips.

There are three new watch folders on systems running Version 2.1:

  • GFX 1/2 for full frame graphics intended to be keyed on to the Graphics 1 and Graphics 2 channels in ViBox.

  • GFX 3 for banner graphics to be used for logos or straps.

  • RTD for replay transitions, files should be compatible with the RTD format.

Software Versions

Contact Support to request a time to schedule an update of your system

This package requires Windows 10 pro 22H2 or Windows 11 Pro IOC to be installed as the OS on the SimplyLive server.

Previous Package (RP-2025-09)

  1. Vibox Backend 11.25.39.45

  2. SimplyLive_SDK_1.25.40.415 (Need to be installed with the Venue Gateway and Vibox Backend)

  3. ViBoxSetup_UI_6_2531_578 (same as previous PRP)

  4. PiPTool 2.25.18.65 (same as previous PRP)

  5. XPort 12.25.21.75 (same as previous PRP)

  6. BMR_6.25.21.19 (same as previous PRP)

  7. MetadataService_3.24.25.9 (same as previous PRP)

  8. RefBox_7.25.28.38 (same as previous PRP)

  9. VenueGateway_14.25.31.06 (same as previous PRP)

New Package SimplyLive 2.1

  1. Vibox Backend 11.26.23.13

  2. Simplylive_SDK_1.26.22.450

  3. ViBoxSetup_UI_6_2622_622

  4. PiPTool 2.26.9.68

  5. XPort 12.26.19.85

  6. BMR_6.26.22.2

  7. MetadataService_3.24.25.9

  8. RefBox_7.26.20.5

  9. VenueGateway_14.26.12.03

  10. Mode_Selector_1.25.31.4

Backend

Prerequisites

  • AJA (same as previous PRP)

    • Driver: 16.1.0.3

    • Firmware: corvid_88_2021-04-28.bit(3F)

  • Blackmagic

    • Driver: Blackmagic_Desktop_Video_Windows_14.4.1

ALWAYS UNINSTALL THE PREVIOUS DRIVER BEFORE UPGRADE TO THE NEW ONE

  • Deltacast (that version is an .exe to run, much more easier)

    • Driver: VideoMaster_Redist_Windows_v6.30.1

  • GPU

    • Driver: 566.14-desktop-win10-win11-64bit-international-nsd-dch-whql.exe

New Features

Key

Summary

SLVE-259

Upgraded WebConfig 1.26.24.238

SLVE-228

Use common frameTime for deltacast

SLVE-226

Provide additional HDR Metadata options

SLVE-186

Support 16 RTD - Protocol/Config Changes

Bug Fixes

Key

Summary

BUG-8079

Resolved intermittent RTD audio drift in 1080p59.94

BUG-7928

Improved Refbox performance in networked environments to reduce A/V network traffic

BUG-7926

Corrected frame rate mismatch for JPEG streams sent to clients in Refbox network mode

BUG-7487

Fixed issue when exporting clips to ProRes MOV (single file, 1080i50 10-bit, new codec)

BUG-7484

Improved progress bar accuracy when exporting ProRes MOV using the 10-bit new codec

BUG-7462

Corrected inaccurate prompt message during export to XDCAM MXF OP1a

BUG-7334

Fixed audio delay management issue in backend web configuration when using 10-bit mode

BUG-7229

Resolved export playlist failure when clip speed was set to 0%

BUG-7140

Fixed incorrect rendering of full-screen logos (Refbox, BMR)

BUG-7104

Resolved audio dropouts when using 10-bit backend with RME audio mixer enabled

BUG-7020

Fixed backend crash when importing clips with 19 audio tracks

BUG-6748

Resolved issues with NDI 4K UHD split handling in the backend

BUG-6539

Fixed timing issue between SSMO and VGW

ViBox UI

New Features

Key

Summary

SLLC-70

Added missing PGM Clean and PGM Dirty options in custom clipping rules, with corrected behavior

SLLC-68

Improved visibility of the “R” indicator in large font mode for ViBox Live with replay channels

SLLC-67

Enhanced ViBox Live experience when using replay channels

SLLC-66

Added visual indication in the ViBox UI when a macro is enabled or active

SLLC-65

Introduced “Wait until end of clip/playlist” option in macros

SLLC-64

Added “Next on Playlist” functionality to keyboard shortcuts and ShuttleXpress

SLLC-62

Added missing “Speed” label in the manual transition tab

SLLC-61

Introduced auto-ingest support for RTD and GFX

SLLC-60

Added preference option to enable preselected audio presets on PGM 1 and PGM 2

SLLC-48

Added shortcut to control Aux 1/2 buttons (ViBox Prod / ViBox Live)

SLLC-34

Increased support for up to 16 RTD channels

SLLC-29

Disabled Take function on RCU when the controlled channel is not set to “All”

SLLC-28

Added option to resynchronize the database without formatting the backend

SLLC-27

Improved functionality of the Next button

SLLC-26

Added SimplyLive certificate to the ViBox installer

SLLC-24

Enhanced API support to improve golf workflows

SLLC-23

Added option to prevent accidental double-clicks on the transition button

SLLC-17

Enabled clip playback during import (manual and automatic modes, without protection)

SL-154

Added Mark Out capability on PGM/PRV/Replay within macros

SL-153

Added option in macros to select PGM or PRV for preload clip/playlist functions

SL-151

Added “Cut playlist item” functionality to ShuttleXpress

SL-149

Added macro controls for ±X frame adjustments on PGM/PRV/Replay

SL-145

Made “Cut playlist item” (including shift-cut via RCU) available in the UI

SL-143

Added ability to rename manual transition buttons in ViBox AIO and Live

Bug Fixes

Key

Summary

SLLC-58

Fixed OSD reconnection issue in ViBox after backend restart

SLLC-57

Resolved issue causing a ghost red zone to appear in the PGM OSD

BUG-8310

Added updated end user license agreement for the ViBox UI installer

BUG-7759

Fixed macro preload clip/playlist functionality to work with all clips, not only the preferred clip

Xport

Bug Fixes

Key

Summary

BUG-7543

Improved playlist export process for 4Kp50 8-bit workflows

BUG-7511

Added missing thumbnails for playlists in Xport

BUG-7206

Fixed failure when exporting SSM at normal frame rate with local path in Xport (DNX MXF OP-ATOM/AAF)

BUG-7107

Corrected layout display for Dirty and Clean outputs in Xport

BUG-6918

Fixed issue where the number of audio tracks changed when switching between Xport profile tabs

BUG-6885

Resolved issue where a save prompt appeared in Xport even when no settings were modified

BMR

New Features

Key

Summary

SLLC-40

Updated transfer characteristics to HLG when exporting 10-bit clips to ProRes MOV and DNxHD MXF

SLLC-37

Added support for ProtocolSDK version 11.25.49.13

SLLC-21

Set the default audio bitrate in the UI to 256 Kbps

SLLC-19

Extended backend support to the maximum number of channels, with status visibility in the UI

Bug Fixes

Key

Summary

BUG-8290

Resolved issue where the BMR REC button error state in ViBox UI was not reset after configuration issues were corrected

BUG-7445

Fixed incomplete display of the “Close BMR” button in BMR

BUG-6822

Resolved filename conflict issues between BMR and SSE when operating alternately on the same server

RefBox

New Features

Key

Summary

SLLC-39

Updated transfer characteristics to HLG when exporting 10-bit clips to ProRes MOV and DNxHD MXF in RefBox

SLLC-35

Addressed security alert related to the use of WinRing in RefBox

SLLC-7

Improved thumbnail resolution for 2-camera layouts

Bug Fixes

Key

Summary

BUG-7745

Aligned RefBox export progress bar behavior with backend export progress

BUG-7731

Fixed issue where .rbc files were not generated when exporting to a server destination

BUG-7720

Corrected recording behavior for PGM 1 Dirty and Clean to follow the refbox_pgm_size configuration

BUG-7697

Standardized prompt messaging across RefBox

BUG-7689

Resolved issue where only one PGM camera was displayed in the Slave UI when two (Dirty and Clean) were configured from the Master

BUG-7617

Fixed issue where exporting multiple clips did not always include the selected camera angles

BUG-7286

Resolved export failures occurring when the destination disk was full

BUG-7283

Corrected layout behavior to ensure background TGA (5×5) is always displayed where required

BUG-7282

Fixed issue where clicking “Apply” caused the full background TGA to disappear

BUG-7251

Resolved issue where user-configured background layouts disappeared after clicking “Apply” on the Master

BUG-7243

Fixed issue where exports did not start when the destination path was unavailable

BUG-7242

Restored functionality of the Import button when the configured export path is no longer available

BUG-6745

Fixed issue where RefBox Mirror clients lost inputs after applying preferences from the Master client

Venue Gateway

Prerequisites

  • Blackmagic

    • Driver: Blackmagic_Desktop_Video_Windows_14.4.1

ALWAYS UNINSTALL THE PREVIOUS DRIVER BEFORE UPGRADE TO THE NEW ONE

  • Deltacast (that version is an .exe to run, much more easier)

    • Driver: videomaster-win.x64-6.30.1

  • GPU

    • Driver: 566.14-desktop-win10-win11-64bit-international-nsd-dch-whql.exe

  • SDK

    • SimplyLive_SDK_1.25.33.391

From that version of Venue Gateway the installer on the SDK in not anymore in the VGW installer, it needs to be installed separately

New Features

Key

Summary

SLVE-47

A new Venue Gateway License Flex, allowing the Venue Gateway to run on the backend and support the “mode selector” application

Bug Fixes

Key

Summary

BUG-7749

Fixed issue when re-adding a channel using a Deltacast board after deletion

BUG-7738

Resolved SRT-to-SDI conversion issue for 1080p50 8-bit streams with Frame Top/Bottom encoding

BUG-7732

Adjusted channel monitoring behavior so that increases in ktSndLossTotal no longer trigger unnecessary yellow blinking indicators

BUG-7730

Fixed issue where preview thumbnails were not displayed when adding a new channel

Web Portal (SDK)

New Features

Key

Summary

SLWA-303

Fixed issue where “Preload Playlist 901” did not function correctly in Clip Companion

SLWA-299

Added new multiviewer layout in SSE to support VSP workflows

SLWA-298

Corrected application port configuration behavior in SSE

SLWA-296

Improved synchronization of clip timecode (TC In/Out) when streaming or scheduling across different servers in SSE

SLWA-293

Resolved issue in SDK Scheduler where TC Out could not be set while ingest was in progress

SLWA-292

Corrected typos and improved grammar in Web Config

SLWA-291

Reordered video standards in Web Config for improved usability

SLWA-290

Updated the monitoring tab in VenueGateway

SLWA-289

Added V.Ref status indicator in the Channels tab of VenueGateway

SLWA-288

Improved grid layout in the Audio Outputs tab of Web Config

SLWA-286

Fixed issue where repeated recordings in SSE ingest could use incorrect dates

SLWA-284

Enhanced VDR UI/UX for Bins and Archive management

SLWA-282

Added improvements to SDK audio encoding (AV)

SLWA-281

Enhanced SDK UI/UX for SSE settings and profile management

SLWA-279

Improved SDK Scheduler UI/UX for task creation and management

SLWA-278

Added ShuttleXpress control support for Multibrowse

SLWA-277

Added VU meter support in Multiview and Multibrowse within the SDK

Bug Fixes

Key

Summary

SLWA-301

Clip Companion: Fixed issues affecting playlist navigation

SLWA-287

Clip Companion: Corrected blue hover indicator behavior following updates

SLWA-268

Clip Companion: Fixed shortcut behavior (Shift + Arrow Left/Right) in search and bin modes

SLWA-267

Clip Companion: Disabled shortcuts when no data is available to prevent unintended actions

SLWA-262

Clip Companion: Resolved issue where the blue hover indicator disappeared from the playlist panel when the search panel was open

SLWA-261

Clip Companion: Fixed issue where bin button names were not updated correctly

SLWA-258

Clip Companion: Corrected blue hover behavior when using Arrow Down on Page 90 (Bank 9)

SLWA-257

Clip Companion: Fixed navigation issue preventing transition from Page 99 to Page 90 using shortcuts

SLWA-256

Clip Companion: Resolved issue where the blue hover indicator disappeared after deleting playlist items

SLWA-255

Clip Companion: Corrected display of bank ID indicators in search mode

SLWA-253

Clip Companion: Fixed blue hover behavior when pages are updated.

SLWA-252

Clip Companion: Resolved inconsistencies in blue hover behavior when switching between clip and playlist views via shortcuts

SLWA-251

Clip Companion: Fixed issue where the blue hover indicator became stuck in playlist view

SLWA-250

Clip Companion: Corrected blue hover navigation when switching between playlist and bin views

SLWA-248

Clip Companion: Improved synchronization of the current playlist

SLWA-214

Venue Gateway: Fixed issue where editing a streaming profile with an empty name caused UI instability.

SLWA-213

Clip Companion: Resolved issue where the blue hover indicator disappeared when changing the view display

SLWA-203

Clip Companion: Fixed intermittent issue where playlists could not be retrieved

SLWA-202

Venue Gateway: Corrected tooltip alignment in the configuration interface

SLWA-189

Clip Companion: Fixed issue where bins for dirty, clean, and imported clips could not be updated

PipTool

New Features

N/A

Bug Fixes

N/A

Metadata Service

New Features

N/A

Bug Fixes

N/A

Mode Selector

New Features

Key

Summary

N/A

Application released

Bug Fixes

N/A

Important notes

Known issues

Key

Summary

Workaround

BUG-7847

ViBox: BITC for RPGM is not correct on SDI outputs

The OSD information on the UI is correct and should be trusted. The Dirty RPGM SDI output and will be addressed in a future release

BUG-8446

VDR shortcuts “R+1” - “R+4” rewind PGM 1, 2, 3 & 4 at “-500%” instead of “-300%”

A known issue that is a validated bug and will be addressed in a future release

BUG-8450

VDR shortcuts “F+1” - “F-4” forward PGM 1, 2, 3 & 4 at “+500%” instead of “+300%”

A known issue that is a validated bug and will be addressed in a future release

BUG-8453

Venue Gateway & Backend: Special characters not escaped in SRT passphrase nor is the string rejected as being invalid

Customers should avoid using special characters in SRT encryption passphrases.

A known issue that is a validated bug and will be addressed in a future release

BUG-8336

Venue Gateway & Backend: SRT output in caller mode always ignores the port

Customers should be aware that the incorrect port will be used until this is resolved. We will address this in the next release

BUG-8346

Backend: 10-bit NDI does not work

NDI 10-bit is not supported, but the integration of the NDI Advanced SDK that will enable 10-bit support is planned for the near-term.

BUG-8349

Backend: External mixer delay is not applied when PGM BITC is applied

We are unable to apply BITC outputs on PGMs in combination with an external audio mixer and a A/V delay. We will address this in the next release