1200-SmartPanels

Main Menu

att_0_for_1939013767.png
Main Menu


Audio Monitoring Source

Calling up this dialog for configuring audio sources is done ...

  • In the main menu by creating a new audio source Add new Audio Monitoring Source.

  • In the main menu by editing an audio source Edit Selected Source, which is marked in the list of audio sources.

  • In the list of audio sources by right-clicking on an entry and selecting the Edit option.

  • In the preview by selecting an audio source by a single click.

Create another Source

If the check box is activated, this dialog remains open after creating (CREATE) an audio source in order to directly configure another audio source.

Cancel

Discard all changes and close the dialog.

Create / Update

Creates the audio source with the current parameters.

att_1_for_1939013767.png
Audio Monitoring Source
(e.g. manual configuration with SDP file)

The parameters are grouped into different sections, each of which can be expanded or collapsed.

Information

Label

Title of the audio source shown in the center of the display.

(max. 8 chars)

Subtitle

Subtitle of the audio source shown at the bottom of the display.

(max. 16 chars)

Color

Selection of the group color for this audio source.

AMS ID

Unique ID of this receiver for identification via NMOS.


Function Behavior

Solo

Enables/disables the solo function for this audio source.

Soloing is done by pressing and holding the lever down.

(Default setting: enabled)

Isolate

Enables/disables the left/right audio channel to be isolated for stereo audio sources.

Isolation is done via the key display/secondary functions.

(Default setting: enabled)


Audio Format

Format

Defines whether the audio source is 'Stereo' or 'Mono'.

(Default setting: Mono)

Source Type

Select whether the audio source is configured manually (or via SDP) or via NMOS. (Default setting: Manual)


Network Leg Options

The Network Leg Options section is only available ...

  • if Source Type is set to 'Manual' in the Audio Format section

Use SDP File

Selection whether the configuration is done via an SDP file.

(Default setting: enabled)

Configure Redundancy *1

Selection of whether a redundant stream is to be configured.

If redundancy is enabled, an additional Secondary Transport Interface section is displayed in the Audio Channel (Leg) area.

(Default setting: disabled)

*1 only if Use SDP File is disabled


If an AMS is created with an SDP file, it must be ensured that the correct format is followed
(->Configuration | Example NMOS Stereo Dual Source).

The Config Tool does not check the SDP files; these are parsed directly by the Audio Monitoring app. A faulty SDP file can therefore result in a non-functioning AMS.

Audio Channel (Leg)

If Stereo is selected as the Format in the Audio Format section, there are two separate Left/Right Audio Channel (Leg) sections.

Play Mode

Selection between 'Synton' and 'Synchron'.

In Synchron mode audio packets will be discarded if the PTP timestamp is missing or invalid. Hence only audio signals are output if they are transmitted in a PTP synchronized network.

In Synton mode audio packets without or with invalid PTP timestamps are processed and output, hence this mode can be used in networks without PTP synchronization. This may lead to increased delay and jitter.

(Default setting: Synchron)

Receive Buffer Factor

Selection of the size of the receive buffer to compensate for runtime differences of the streams. (3 ... 112 / default setting: 8)

Channel Selection *2

Sets the audio channel to be received.

Use SDP for all *2, 3

Select whether the SDP settings are also valid for the left/right stream.

(Default setting: enabled)

SDP file *2, 4

Button to open a dialog where the stream settings can be loaded from an SDP file.

Create one NMOS Receiver for both Channels *3, 5

Only one NMOS receiver is generated for both channels.

(Default setting: disabled)

*2 only if Source Type is set to 'Manual' in the 'Audio Format' section

*3 only if Format is set to 'Stereo' in the 'Audio Format' section

*4 only if Use SDP File is enabled in the 'Network Leg Options' section

*5 only if Source Type is set to 'NMOS' in the 'Audio Format' section


Audio

The Audio section is only available ...

  • if Source Type is set to 'Manual' in the Audio Format section and

  • if the Use SDP File option is disabled in the Network Leg Options section.

Bit Depth

Selection of the resolution.

(L16, L24 / default setting: L24)

Media Clock Offset

Selection of the Time Stamp Offset.

(0 ... 65535 ms / default setting: 0)

Number of Channels

Amount of used audio channels in the stream.

(1 ... n / default setting: 1)

Packet Time

Packet time is the real-time duration of media data in a packet. Samples per packet are calculated from packet time and sampling rate. Short packet time allows for lower latency but requires more bandwidth due to overhead. Implemented for interoperability reasons.

Depending on selected amount of audio channels and the bit depth, shorter packet times are available.

(0.125, 0.25, 0.333, 0.5, 1, 1.333 or 4 ms / default setting: 1)

Payload Type

Selection of the Payload type.

(96 ... 127 / default setting: 96)

Sample Rate

Selection of the sampling rate.

(44.1, 48 or 96 kHz / default setting: 48)

Primary/Secondary Transport Interface

The Secondary Transport Interface section is only available ...

  • if Source Type is set to 'Manual' in the Audio Format section and

  • if the Configure Redundancy option is enabled in the Network Leg Options section.

Multicast IP

Source address of the Audio Monitor Source.

Multicast Port

Source port of the Audio Monitor Source. (1024 ... 65535 / default setting: 5004)

Sender IP

IP address of the audio source.

Sender Port

IP port of the audio source. (1024 ... 65535 / default setting: 5004)


This information must be known for creation and either comes automatically from the SDP file (if loaded) or is entered manually.

To check which media interface is used for AMA, a web interface can be called with the IP address of the SmartPanel and the addition "/ama/v1.0/media-state" (e.g. http://192.168.41.212/ama/v1.0/media-state).

If 2022-7 is active, media1State and media2State are displayed as Active.

att_4_for_1939013767.png

AMA Configuration

Calling up this dialog for the general configuration of the Audio Monitoring app is done ...

  • In the main menu by clicking 'AMA Configuration'.

att_5_for_1939013767.png
AMA Configuration


The parameters are grouped into different categories, each of which can be expanded or collapsed.

AMA App Enable

Enables/disables the Audio Monitoring App on the SmartPanel.

(Default setting: enabled)

Local Persistence

Enables/disables local persistence.

If this function is deactivated, the audio sources currently configured on the keys are not restored after a restart of the SmartPanel.

(Default setting: enabled)


Audio

Trim Level in dB

Setting the level of all monitored audio sources.

(-72.3 ... +18 dB / default setting: 0)

NMOS IS-08 Channel Order

Sets the order (top/bottom) of the left and right audio channels.

(Left|Right, Right|Left / default setting: Left|Right)


Display

Group Color Display Location

  • None: No group color is displayed.

  • On Display: The group color is shown as a border in the display.

  • On Keyring: The group color is displayed in the LED ring.

(Default setting: None)

Peak Meter Clipping

Enables/disables the warning in case of a clipping audio source.

(Default setting: disabled)

Clip Indication Timeout in ms

Sets the time how long a clipping audio signal is signaled.

(1000 ... 10000 ms / default setting: 3000)

Input

Secondary Drawer Behavior

Enables/disables the Key Display Functions (Secondary Function Drawer) of the SmartPanel. (Default setting: enabled)


Inter App Behavior

AMA Ducking

  • Disabled: The monitored audio source is never dimmed.

  • -3 ... -24 dB: Setting of the level (in 3 dB steps) at which a monitored audio source is dimmed when an intercom call is received at the SmartPanel.

  • Mute: The monitored audio source is muted when an intercom call is received at the SmartPanel.

(Default setting: Mute)

Intercom Headset Ducking

  • Disabled: The intercom audio is never dimmed in the headset.

  • -3 ... -24 dB: Setting of the level (in 3 dB steps) at which the intercom audio in the headset is dimmed as long as the lever for the solo function is held down.

  • Mute: The intercom audio is muted in the headset as long as the lever for the solo function is held down.

(Default setting: -9)

Intercom Speaker Ducking

  • Disabled: The intercom audio is never dimmed in the speaker.

  • -3 ... -24 dB: Setting of the level (in 3 dB steps) at which the intercom audio in the speaker is dimmed as long as the lever for the solo function is held down.

  • Mute: The intercom audio is muted in the speaker as long as the lever for the solo function is held down.

(Default setting: -9)


Keybank

Color

Selection of the color with which the Audio Monitoring app appears in the info display. (Default setting: Aquamarine)

Name

Enter the name of the Audio Monitoring app that is shown in the info display. (Default setting: Monitoring)

NMOS Configuration

att_6_for_1939013767.png
NMOS Configuration


The NMOS configuration contains the following parameters:

Node Port

Input of the Ethernet port.

(1024 ... 65535, default setting: 8080)

IS-04 Versions

Selection of NMOS versions to be supported.

(Unknown, v1_1, v1_2, v1_3, default setting: v1_3)

Search Domain

Entering the domain.

Registration Mode

  • Static: NMOS tries to connect to the NMOS registry specified in entries in the Registry section (IP address, port, NMOS version).

  • Auto: NMOS uses IS04 to determine the NMOS registration on the subnet. If there is an NMOS registration, this node connects to it directly. If not, it switches to P2P mode.

  • P2P: The NMOS node searches for other nodes directly via mDNS instead of relying on the NMOS registry.

The NMOS status can be checked in the web interface of the SmartPanel (->Device Settings | NMOS Registration).

att_7_for_1939013767.png

If NMOS is to be used, the use of an NMOS registration server is recommended.
The NMOS peer-to-peer mode uses mDNS and only works in Layer 2 network environments.

AMA always expects an IS-08 audio channel mapping in NMOS mode. There is no default mapping of AES67 stream channel to the panel L/R audio channel. This means for every NMOS AMS the AES67 channels must be mapped before the AMS appears as online in the AMA keybank and audio can be monitored.


Import Audio Monitoring Sources

This function can be used to import the user-defined audio sources that were previously saved as a JSON file. A dialog opens where the corresponding file can be selected. After pressing the Open button, all the audio sources present in the file are displayed in the list of audio sources.

Audio sources that are already present in the list of the connected SmartPanel are ignored during import. The import function must be executed separately for each SmartPanel.


Export Audio Monitoring Sources

With this function, all audio sources present in the list can be saved as a JSON file. In the dialog, navigate to the desired folder and specify a file name. After clicking the Save button, the audio sources with all parameters are written to the file.

Only data from the connected SmartPanel is saved in each file.
The export function must be executed separately for each SmartPanel.