Physical Connection
The RC-200 connects to ViBox Slomo by Ethernet, either:
-
To a network switch
-
Directly into the client or server
-
Via a USB RJ45 adapter
Assign the NIC to the RCU range
Set the NIC the RC-200 is plugged into to a static IP in the same range as the panel.
Example: RC-200 on 192.168.1.200 → NIC on 192.168.1.10
To change the panel’s IP, see SL_ Changing RC-200 IP Address.
Link to ViBox Slomo
-
ViBox UI > Setup > Prefs
-
Select RCU 1 (or RCU 2 for a second panel)
-
Set the remote to RC-200 and enter its IP address
The RC-200 goes live once the ViBox UI is open and the IP is set.