Lawo mc² UHD Series Audio Console Integration Configuration
Caution
Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.
Configuration Overview
An mc² UHD console connects to hi as one Node through the MCX Ember+ provider. The Node has two capabilities on the same address and Port: Crosspoint Management for the audio signal matrix, and Parameter Control for the Ember+ tree. hi names each Port from the Lawo user label of its signal.
|
Configuration |
What hi Sees |
Use When |
|---|---|---|
|
mc² UHD Routing and Parameters |
The audio matrix at |
hi must route mc² UHD signals, or monitor and change mc² UHD parameters. |
Caution
Confirm that the installed MCX release publishes the signalMatrix branch. From MCX release 10.4 (build 9 of 10.4.0), the console also disconnects external Ember+ connections when a production is loaded.
Before You Begin
-
Use Node admin and open Inventory > Nodes. See Manage Nodes.
-
Confirm the license and minimum hi version in Required Configuration.
-
Confirm the installed MCX release, and use the Lawo tooling for the signal labels.
-
Confirm the network access in Network Requirements.
Configure mc² UHD Routing and Parameters
Device Configuration
-
Confirm that the console publishes the
signalMatrixbranch, and that the Ember+ provider is enabled. The MCX Ember+ provider uses TCP Port9000, the hi default. -
Give a user label to each signal that hi must show by name.
-
Record the console address and the provider Port. Ensure that the hi server can reach the provider.
hi Configuration
-
Add the mc² UHD Series Audio Console integration (manufacturer Lawo) in Inventory.
-
Enter the console address and the provider Port for the Crosspoint Management capability and for the Parameter Control capability. hi defaults both to
9000. -
Create the Node and wait for hi to read the signal matrix and labels.
-
After the Node is created, set Overwrite Names in the Startup group. With
Yes, the default, hi replaces the Port names with the console labels when it reconnects. WithNo, hi keeps the Port names that it has. -
After the Node is created, use Refresh Labels in the Operations group to read the console labels again. hi restarts the connection to read them.
-
Browse the parameter tree of the Node and pin the parameters that your workflow needs. See Parameter Control Nodes.
Settings Summary
|
Setting |
Device Side |
hi Side |
|---|---|---|
|
Control Port |
Ember+ provider Port |
Port of both capabilities
|
|
Signal matrix |
|
Read automatically
|
|
Port names |
User label of each signal |
Port names
|
Common Checks
|
Symptom |
Check |
|---|---|
|
The Node connects, but no Sources or Destinations appear. |
Confirm that the installed MCX release publishes the |
|
The Node disconnects and reconnects. |
Check whether a production was loaded, or whether the signal matrix changed on the console. hi reads the console again in both cases. |
|
A Port shows Input or Output followed by a number. |
Give the signal a user label on the console, then use Refresh Labels. |
|
A label edited in hi changes back after a reconnect. |
Set Overwrite Names to |
Verify the Configuration
Confirm that the signal matrix and the pinned parameters appear in hi. Compare the Port names in hi with the console labels. Route a noncritical Destination from hi and confirm the change in the Lawo tooling. Change a pinned, noncritical parameter from hi and confirm the change in the Lawo tooling. Change the same parameter in the Lawo tooling and confirm that the new value appears in hi.