STAGETEC Audio Console
Production
Recommended for normal production use.
Caution
Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.
Minimum hi Version: v2.4.1
Overview
The STAGETEC® audio-console integration uses Ember+ through XACI for Crosspoint routing and the parameters published by the console.
Network Requirements
-
Connection Model: Outbound from hi
-
Multicast / Unicast: Unicast only
-
Firewall: Allow outbound TCP from hi to the XACI interface on Port
9003by default. -
Callback: No inbound callback to hi is used.
-
Security: Keep the plaintext control connection on a trusted management network.
Standards Conformance
|
Standard |
Conformance |
Notes |
|---|---|---|
|
Ember+ (Lawo) |
Glow DTD parameter tree per Ember+ spec |
Matrix and parameter tree access through XACI |
Operator Workflow
-
UI Surface in hi: Inventory, Parameter Control, and Control Panels
-
Layers Controlled: Audio, Control
-
Routing Semantics: hi exposes the Ember+ matrix and parameters published through XACI.
-
Notes for Operators Familiar with the Vendor's Own Tooling: The exact controls available in hi are defined by the published Ember+ tree. Use STAGETEC tooling for DSP design and show-file configuration.
Connection Details
|
Property |
Value |
|---|---|
|
Protocol |
Ember+ |
|
Transport |
TCP |
|
Default Port |
9003 |
|
Authentication |
No credentials are configured by this hi integration |
|
Encryption in Transit |
None - Ember+ uses plaintext TCP
|
|
Connection Model |
Persistent TCP with subscription through the XACI card |
|
Required License |
hiBase |
|
Traffic Flow |
Outbound from hi |
Required Configuration
|
Parameter |
Description |
Default |
|---|---|---|
|
Host / IP Address |
IP address of the XACI card interface |
- |
|
Port |
Ember+ TCP Port on the XACI card |
9003 |
|
Reinitialize Router |
Operations button that disconnects the routing control connection and restarts initialization
|
- |
Device-Side Setup
Follow STAGETEC Audio Console Integration Configuration for the device-side and hi-side configuration steps.
Supported Features
|
Feature |
Access |
Exposed Operation and Scope |
|---|---|---|
|
Ember+ Crosspoint Routing |
Read/write |
Read routing state and set exposed Crosspoints through the XACI card. |
|
Parameter Tree (GetDirectory) |
Read-only |
Discover the tree and read values exposed by the XACI Ember+ provider. |
|
Parameter Values (Set) |
Per-parameter access |
Write only parameters the provider marks writable. |
|
Parameter Subscriptions (Subscribe / Unsubscribe) |
Read-only updates |
Subscribe to and receive exposed value changes; unsubscribe removes the hi subscription. |
Device Coverage
Tested With identifies devices that have been tested with hi. Potentially Compatible (Not Yet Verified) identifies compatibility candidates that use the same protocol or connection method. Device-specific configuration, firmware, and feature support can affect results.
Tested With
-
STAGETEC NEXUS with XACI board
Potentially Compatible (Not Yet Verified)
-
STAGETEC products that provide Ember+ directly, such as AVATUS and NEXUS compact, where they expose a compatible Ember+ parameter tree and writable matrix. These products use Port
9000, not the XACI Port9003.
Known Limitations
-
For the NEXUS configuration tested through XACI, install an XACI board. Its Ember+ provider is active by default on Port
9003. -
STAGETEC specifies and implements the XACI requirements when it designs the NEXUS system. The XACI board has no parameters in the NEXUS matrix software; set its network settings in the NEXUS service program.
-
STAGETEC documents Ember+ on Port
9000for products that provide it directly, such as AVATUS and NEXUS compact, and Port9003for the XACI board. hi defaults to Port9003; confirm the Port in the device documentation before connecting a different product. -
On an XACI board, Port
9000serves the NEXUS 4split web interface, not Ember+. Connect hi to Port9003on the XACI board. -
Validate the available Ember+ tree during commissioning.
-
hi reads only the audio matrix that the provider publishes at the
Audio/Matrixnode. Other matrices in the tree do not appear in hi. -
hi subscribes only to the parameters that are pinned on the Node. Other parameters in the tree do not update in hi.
-
hi sends an Ember+ keep-alive request every 5 seconds, and it disconnects when the provider does not answer within 10 seconds. hi requires the provider to answer keep-alive requests.
What's Not Supported
-
Firmware updates and DSP design - use the vendor's native software, such as its show-file editor or channel-configuration tool.
-
Offline scene and show-file programming remain in the vendor tooling.
-
Audio metering visualization beyond basic level readback where exposed by the protocol.
-
Ember+ Functions, including Qualified Functions, and function invocation. The Ember+ specification defines them from Glow 2.20, and hi never sends an Invoke command.
-
Ember+ Templates, including Qualified Templates, and template references. The specification defines them from Glow 2.40. hi requests all fields of each element, and it does not resolve template references.
Trademarks
Note
STAGETEC is a registered trademark of STAGETEC Entwicklungsgesellschaft für professionelle Audiotechnik GmbH.
RIEDEL Communications is not affiliated with, endorsed by, or officially partnered with STAGETEC unless explicitly stated.