hi human interface®
English

hiContact (Mark 1)

This page describes the hiContact (Mark 1) GPIO box and its specifications.

hiContact (Mark 1)

Mark 1

The hiContact Mark 1 is a one-third-width 19-inch 1RU GPIO box with 16 isolated inputs, 16 relay outputs, a front status display, and an external power supply. Three units fit across one 1RU rack space.

Information

Discontinued: This product has been discontinued and is no longer actively maintained or supported. Devices may continue to operate as expected, but future development of this platform is not planned.

Dimensional Views

Front View

Dimensioned Front View of the hiContact Mark 1 GPIO Box

hiContact Mark 1 Front View.

Rear View

Dimensioned Rear View of the hiContact Mark 1 GPIO Box

hiContact Mark 1 Rear View.

Bottom View

Dimensioned Bottom View of the hiContact Mark 1 GPIO Box Showing the Mounting Holes

hiContact Mark 1 Bottom View.

Specifications

Warning

This model is specified for DC input signals and relay circuits only. Do not connect AC or mains voltage. Do not exceed 20 V DC on an input, or 30 V DC and 1 A on a relay contact.

Property

Specification

Type number

hi-IO1616

Weight

520 g

Inputs

16 opto-electronically isolated inputs

Outputs

16 relay outputs

Housing type

One-third of a 19-inch rack unit
three units fit in 1RU

Connector-face dimensions (W x H)

140 x 44 mm

Overall dimensions (W x H x D)

144 x 43 x 100 mm

Network connection

RJ45, 10Base-T Ethernet

Storage temperature range

-20 °C to +80 °C

Input voltage

11 V to 13 V DC

Maximum power consumption

20 W

Attached power supply

CUI SDI30-12-U-P5
use only the supplied power supply

Power connector

WAGO 713 Series
6-pin

Input and output connectors

WAGO 713 Series
16-pin

Maximum input voltage

20 V DC

Maximum relay switching voltage

30 V DC

Maximum relay switching current

1 A

Protection class

IP20

Conformity marking

CE

EMC emissions

EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55032:2015

EMC immunity

EN 55024:2010+A1:2015

RoHS reference

EN 50581:2012

Lifecycle Status

Discontinued

EC Declaration of Conformity

Dated 23 August 2019
covers type HI-IO1616

Directives named in declaration

EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU

TÜV Rheinland EMC test report

No. 28251341 001 for HI-IO1616
sample test result: pass

GPIO Connector Layout

The two 16-pin connectors on the left are inputs. The two connectors on the right are outputs. The marked input pins connect internally to GND. Do not exceed 20 V DC on an input pin.

Relay contacts switch an external circuit and do not supply its voltage. Keep each switched circuit within the limits in Specifications.

Commissioning

The default IP address is 192.168.1.100, and the device uses plug-and-play commissioning. To change the IP address, contact Riedel Customer Success.

For installation and commissioning instructions, see Hardware Installation and Commissioning. For routine care, see Hardware Cleaning and Maintenance. Review Hardware Network Configuration for shared network setup guidance.

Ordering Information

This model is discontinued and is no longer available for new orders. Use the type number in Specifications to identify installed hardware.

Power Connector Pinout

WAGO 713 Series 6-Pin Power Connector Pinout for hiContact Mark 1, Including the Connector Diagram and Electrical Pin Assignments