This page describes the hiContact (Mark 1) GPIO box and its specifications.
hiContact (Mark 1)
Mark 1
The hiContact Mark 1 is a one-third-width 19-inch 1RU GPIO box with 16 isolated inputs, 16 relay outputs, a front status display, and an external power supply. Three units fit across one 1RU rack space.
Information
Discontinued: This product has been discontinued and is no longer actively maintained or supported. Devices may continue to operate as expected, but future development of this platform is not planned.
Dimensional Views
Front View
hiContact Mark 1 Front View.
Rear View
hiContact Mark 1 Rear View.
Bottom View
hiContact Mark 1 Bottom View.
Specifications
Warning
This model is specified for DC input signals and relay circuits only. Do not connect AC or mains voltage. Do not exceed 20 V DC on an input, or 30 V DC and 1 A on a relay contact.
|
Property |
Specification |
|---|---|
|
Type number |
hi-IO1616 |
|
Weight |
520 g |
|
Inputs |
16 opto-electronically isolated inputs |
|
Outputs |
16 relay outputs |
|
Housing type |
One-third of a 19-inch rack unit
|
|
Connector-face dimensions (W x H) |
140 x 44 mm |
|
Overall dimensions (W x H x D) |
144 x 43 x 100 mm |
|
Network connection |
RJ45, 10Base-T Ethernet |
|
Storage temperature range |
-20 °C to +80 °C |
|
Input voltage |
11 V to 13 V DC |
|
Maximum power consumption |
20 W |
|
Attached power supply |
CUI SDI30-12-U-P5
|
|
Power connector |
WAGO 713 Series
|
|
Input and output connectors |
WAGO 713 Series
|
|
Maximum input voltage |
20 V DC |
|
Maximum relay switching voltage |
30 V DC |
|
Maximum relay switching current |
1 A |
|
Protection class |
IP20 |
|
Conformity marking |
CE |
|
EMC emissions |
EN 61000-3-2:2014
|
|
EMC immunity |
EN 55024:2010+A1:2015 |
|
RoHS reference |
EN 50581:2012 |
|
Lifecycle Status |
Discontinued |
|
EC Declaration of Conformity |
Dated 23 August 2019
|
|
Directives named in declaration |
EMC Directive 2014/30/EU
|
|
TÜV Rheinland EMC test report |
No. 28251341 001 for HI-IO1616
|
GPIO Connector Layout
The two 16-pin connectors on the left are inputs. The two connectors on the right are outputs. The marked input pins connect internally to GND. Do not exceed 20 V DC on an input pin.
Relay contacts switch an external circuit and do not supply its voltage. Keep each switched circuit within the limits in Specifications.
Commissioning
The default IP address is 192.168.1.100, and the device uses plug-and-play commissioning. To change the IP address, contact Riedel Customer Success.
For installation and commissioning instructions, see Hardware Installation and Commissioning. For routine care, see Hardware Cleaning and Maintenance. Review Hardware Network Configuration for shared network setup guidance.
Ordering Information
This model is discontinued and is no longer available for new orders. Use the type number in Specifications to identify installed hardware.
Power Connector Pinout