Riedel hiPush Series

Driver Maturity

Production

Recommended for normal production use.

Caution

Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.

Available controls vary by product and hardware generation.

Minimum hi Version: v1.1.0

Overview

The Riedel hiPush™ family uses the proprietary hi Hardware Panel protocol. The panel initiates a persistent connection to the hi system, and control data then flows in both directions.

Supported products are hiPush18, hiPush20, hiPush32-D, hiPush32-S, hiPush36, and hiPush54.

The Hardware User Manual summarizes the product range. Use the current Riedel product datasheet as the authoritative source for hardware specifications.

Network Requirements

  • Connection Model: Inbound to hi from the panel; bidirectional after connection.

  • Multicast / Unicast: Unicast only.

  • Bandwidth: Control data only.

  • IP Version: IPv4.

  • Firewall: Allow the panel to reach the configured hi Hardware Panel service.

Operator Workflow

hiPush panels use the Hardware Panel editor, Router Panel Preset delegation, Static Preset layouts, and the Hardware Panel simulator where supported by the selected product. Operators can assign buttons and rotaries to routing, disconnect, Parameters, Triggers, Presets, and Destination locks.

Connection Details

Property

Value

Protocol

hi Hardware Panel protocol (proprietary)

Transport

TCP / WebSocket

Default Port

Not specified (device-dependent)

Authentication

Not specified (device-dependent)

Encryption in Transit

Not specified (device-dependent)

Connection Model

Persistent connection initiated by the panel

Required License

hiGlue

Traffic Flow

Bidirectional

Required Configuration

The integration requires hiGlue. Each connected panel also consumes one hiUser session. Confirm available capacity using hiUser before connecting panels.

The panel must be configured to reach the assigned hi Hardware Panel service. On connection, the panel registers its identity and hardware description with hi.

Device-Side Setup

Follow Riedel hiPush Series Integration Configuration for the device-side and hi-side configuration steps.

Supported Features

Feature

Access

Exposed Operation and Scope

Button and Rotary Input

Read-only input

Receive actuation, rotary movement, and rotary push where the selected product provides them.

Presets and Layouts

hi-side configuration and write actions

Delegate Presets and configure supported panel layouts.

Routing

Read/write actions

Route, take, disconnect, and select entries from Port Containers.

Parameters

Per-parameter access

Read and write only Parameters whose hi access mode permits the requested operation.

Triggers

Write-only actions

Execute configured triggers.

Destination Locking

Read/write

Apply and display Destination lock state.

Displays and Indicators

Write-only panel output

Update button/display content, LEDs, and meters where provided by the selected product.

Panel Operation

Read/write and read-only status

Register the panel, synchronize initial data, and control standby state.

Device Coverage

The following product layouts and controls are available.

This integration supports the Riedel hiPush range.

Tested With identifies devices that have been tested with hi.

Tested With

  • Riedel hiPush36

  • Riedel hiPush54

Supported Product Range

Product

Implemented Controls

hiPush18

18 buttons and 2 rotaries
Mark 1 has 0 meters, while Mark 2 and supported Mark 3 have 2 meters

hiPush20

20 buttons

hiPush32-D

32 buttons
2 rotaries
and 2 meters

hiPush32-S

32 buttons
2 rotaries
and 2 meters

hiPush36

36 buttons
2 rotaries
and 2 meters

hiPush54

54 buttons and 2 rotaries
Mark 1 has 0 meters, while Mark 2 and supported Mark 3 have 2 meters

Known Limitations

  • Available indicators and meters depend on the selected hiPush product.

  • Static Presets are not available on hiPush32-D or hiPush32-S.

  • hi identifies a connecting panel by its source IP address. The address entered on the Node must match the panel's own IP address. hi does not register a panel whose address matches no enabled Node.

  • When two enabled Nodes use the same panel IP address, hi uses only the first match.

  • After registration, hi records the MAC address and firmware version that the panel reports.

What's Not Supported

  • Firmware updates, physical commissioning, and hardware diagnostics are outside this integration.

  • Standalone offline operation is outside the hi Hardware Panel workflow.

Trademarks

Note