Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.

Configuration Overview

The Kahuna and Kula integration uses two independent connections. The GV Kahuna Tally connection receives Tally from the switcher. The TSL connection sends dynamic Source labels to it. Configure Tally first, then add Dynamic Labels when the switcher displays hi names.

Configuration

What hi Sees

Use When

Receive Tally

Source Tally from the switcher.

Always. Configure this first.

Send Dynamic Labels

hi sends Source names to the switcher through TSL.

The switcher displays labels from hi.

Caution

The two connections use different Ports. Do not enter the Tally Port for the label connection.

Before You Begin

  • Use Node admin and open Inventory > Nodes. See Manage Nodes.

  • Confirm the license in Required Configuration.

  • Use the Grass Valley tooling for the switcher. See the vendor documentation for the Tally and TSL interfaces.

  • Confirm the network access in Network Requirements.

  • Record the switcher address and the separate Tally and dynamic-label Ports.

Configure Receive Tally

Use this configuration to receive Tally from the switcher.

Device Configuration

  1. On the switcher, open Engineering Config > Protocols. Set Protocol Type to Tally & UMD, select Kahuna Tally in Available Protocols, and select Load.

  2. Select Configure..., set the connection, select Apply, and then select Activate. The protocol is available only when the matching Kahuna protocol option is installed.

  3. Record the Tally Port. hi defaults to 50001.

hi Configuration

  1. Add the Kahuna / Kula Series integration in Inventory.

  2. Enter the switcher address and the Tally Port. hi defaults to 50001.

  3. Create the Node and wait for it to initialize.

  4. Assign the received Tally to hi Tally Sources. See Manage Tally.

Configure Send Dynamic Labels

Use this configuration after Tally works and the switcher must display hi names.

hi sends the label of Source N to TSL address N − 1. This integration has no TSL Address Offset setting.

Device Configuration

  1. On the switcher, open Engineering Config > Protocols. Set Protocol Type to Tally & UMD, load TSL UMD (Input Only), and configure and activate it. The switcher maps each received Source name to a UMD address.

  2. In Engineering Config > Input Setup, enable Router Overwrite so that received names replace the default input names.

  3. Record the Port, TSL variant, and transport of the label receiver. hi defaults to 50014.

hi Configuration

  1. Open the Node.

  2. In the Dynamic Labels capability, enter the switcher address and the label Port. hi defaults to 50014.

  3. Select the Label Protocol and Label Transport that the switcher uses.

  4. Complete the Dynamic Labels tab. See Dynamic Label Setup.

Settings Summary

Setting

Device Side

hi Side

TSL variant

The variant of the label receiver

Label Protocol

Transport

The transport of the label receiver

Label Transport

Port

Port of the label receiver

Label Port

Common Checks

Symptom

Check

Tally arrives but labels do not.

Confirm the label Port, Label Protocol, and Label Transport. They are separate from the Tally connection.

Labels arrive but Tally does not.

Confirm that the Kahuna Tally interface is enabled on the switcher and that the Tally Port matches. It is separate from the label connection.

Verify the Configuration