hi human interface®
English

Imagine Communications Selenio Network Processor (SNP)

Imagine Communications Selenio Network Processor (SNP)

Driver Maturity

Production

Recommended for normal production use.

Caution

Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.

Minimum hi Version: v2.8.0

Overview

hi controls the Imagine Communications® Selenio™ Network Processor using CCS-P over TCP or UDP. The integration reads and writes processing parameters, and monitors status. AudioFlex™ controls appear when the SNP exposes them.

Network Requirements

  • Connection Model: hi initiates the selected TCP or UDP exchange.

  • Multicast / Unicast: Unicast TCP or UDP.

  • VLAN / IGMP: No multicast configuration is required.

  • Bandwidth: Control traffic only.

  • IP Version: IPv4.

  • Firewall: Allow TCP from hi to the SNP on Port 4517, or UDP to the SNP on Port 4050 when UDP is selected. With UDP, also allow inbound UDP from the SNP to Port 4000 on the hi server, because hi receives CCS-P messages on that local Port.

Standards Conformance

Standard

Conformance

Notes

Imagine Communications CCS-P

Version 1.1

SNP parameter and status exchange over TCP or UDP

Operator Workflow

  • UI Surface in hi: Inventory and Parameter Control

  • Resources Controlled: Processing parameters, AudioFlex controls, and status published by the SNP

  • Device Administration: Use Imagine Communications tooling for provisioning, licenses, and firmware.

Connection Details

Property

Value

Protocol

Imagine CCS-P 1.1

Transport

TCP or UDP

Default Port

4517

Authentication

None sent by hi. The CCS-P specification defines an optional authentication string that a server can use. hi does not send one.

Encryption in Transit

None
the TCP and UDP transports are plaintext

Connection Model

Configurable TCP or UDP command and response exchange

Required License

hiBase

Traffic Flow

Outbound requests with inbound responses and status updates

Required Configuration

Parameter

Description

Default

Host / IP Address

IP address of the Selenio SNP

-

Port

CCS-P Port

4517

Network Transport

CCS-P network transport

TCP

Device-Side Setup

Follow Imagine Communications Selenio Network Processor (SNP) Integration Configuration for the device-side and hi-side configuration steps.

Supported Features

Feature

Access

Exposed Operation and Scope

Parameter Write (Assign)

Per-parameter access

Write CCS-P parameters the SNP exposes as writable; parameters marked non-writable are read-only in hi.

Parameter Query

Read-only

Query published values.

Parameter Tables

Per-parameter access

Read and write the integer, string, and enumeration cells of parameter tables that the SNP publishes.

Response and Status

Read-only events

Receive parameter responses and device-status updates.

AudioFlex Parameters

Per-parameter access

Available only when the SNP publishes them through CCS-P; their access follows the published parameter. This is not a separate AudioFlex API.

Device Coverage

Tested With identifies devices that have been tested with hi. Potentially Compatible (Not Yet Verified) identifies devices that use the same protocol or connection method but have not been tested with hi. Device-specific configuration, firmware, and feature support can affect results.

Tested With

  • Imagine Communications Selenio Network Processor (SNP)

Potentially Compatible (Not Yet Verified)

Other Imagine Communications devices that publish a CCS-P parameter tree use the Imagine Communications CCS-P Parameter Controllable Device integration.

Known Limitations

  • AudioFlex features depend on the specific SNP configuration and licensed options.

  • The SNP serves CCS-P on TCP port 4517 and UDP port 4050. The default Port is 4517; when you select UDP, enter the UDP port that the SNP uses.

  • The SNP Manager in the vendor's console view includes a CCSP Interface Documentation section with a link to the parameter tree and alarm list. Use it to confirm the parameters that the SNP publishes.

  • If the Parameter tree is incomplete, confirm that the SNP publishes the required CCS-P functions for the selected transport.

  • With UDP, hi expects a keep-alive from the device within 25 seconds, then requests one and waits another 25 seconds before it treats the device as disconnected. With TCP, hi sends a keep-alive every 25 seconds.

  • When hi connects, it loads the top four levels of the CCS-P tree and the enumeration types that the SNP publishes. hi loads deeper levels when you open them in the Parameter Browser.

  • Network Transport defaults to TCP. It is available when you create the Node and afterward. The Port does not change with the transport.

What's Not Supported

  • Firmware updates, license administration, and base hardware provisioning.

  • CCS-P methods and function invocation, relative adjustments (Adjust and AdjustCoarse), SetDefault, and the static, dynamic, method, and identifier queries. The protocol defines them, and hi uses only Query and Assign for Parameters.

  • CCS-P alarms, alarm tables, and device alarm state.

Trademarks

Note

Imagine Communications, Selenio, and AudioFlex are trademarks of Imagine Communications Corp.

All product names, logos, and brands are property of their respective owners. Copyright in third-party software and materials remains with the respective owners. Use of these names does not imply endorsement.

RIEDEL Communications is not affiliated with, endorsed by, or officially partnered with Imagine Communications unless explicitly stated.