Imagine Communications Selenio Network Processor (SNP) Integration Configuration
Caution
Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.
Configuration Overview
The SNP connects to hi as one Parameter Control Node over TCP or UDP. The SNP uses a different CCSP server Port for each transport, so the transport and the Port in hi must match.
|
Configuration |
What hi Sees |
Use When |
|---|---|---|
|
CCS-P over TCP |
The SNP parameter tree. hi sends keep-alives to the SNP. |
Default. Use it unless the SNP must use UDP. |
|
CCS-P over UDP |
The SNP parameter tree. hi expects keep-alives from the SNP. |
The SNP must use UDP. |
Caution
hi does not change the Port when you change Network Transport. When you select UDP, enter the UDP Port of the SNP, because the pre-filled 4517 is the TCP Port.
Before You Begin
-
Use Node admin and open Inventory > Nodes. See Manage Nodes.
-
Confirm the license and minimum hi version in Required Configuration.
-
Obtain access to the SNP Manager and the Selenio Network Processor User Guide.
-
Confirm the network access in Network Requirements.
Configure CCS-P Over TCP
Use this configuration for a standard SNP connection.
Device Configuration
-
In the SNP Manager, open Configure Element for the SNP, select the System tab, and in the Security section clear Disable CCSP Port. The SNP then serves CCS-P on TCP Port
4517. -
In the SNP Manager console view, open the CCSP Interface Documentation section and confirm the parameters that the SNP publishes.
hi Configuration
-
Add the SNP integration, manufacturer Imagine Communications, in Inventory.
-
Enter the SNP address. Keep the Port at
4517. -
In the Connection Settings group, keep Network Transport at
TCP. -
Create the Node. hi loads the top four levels of the CCS-P tree.
-
In the Parameter Browser, open the branches that you need, select the parameters that hi must monitor, and select Pin Selected.
Configure CCS-P Over UDP
Use this configuration only when the SNP must use UDP.
Device Configuration
-
In the SNP Manager, open Configure Element for the SNP, select the System tab, and in the Security section clear Disable CCSP Port. The SNP then serves CCS-P on UDP Port
4050. -
In the SNP Manager console view, open the CCSP Interface Documentation section and confirm the parameters that the SNP publishes.
hi Configuration
-
Add the SNP integration, manufacturer Imagine Communications, in Inventory.
-
Enter the SNP address and replace the Port with
4050. -
In the Connection Settings group, set Network Transport to
UDP. -
Allow inbound UDP from the SNP to Port
4000on the hi server. -
Create the Node. hi loads the top four levels of the CCS-P tree.
-
In the Parameter Browser, open the branches that you need, select the parameters that hi must monitor, and select Pin Selected.
Settings Summary
|
Setting |
Device Side |
hi Side |
|---|---|---|
|
Transport |
TCP or UDP CCSP server |
Network Transport
|
|
Port |
TCP |
Port
|
|
UDP replies |
Messages to the hi server |
Local UDP Port |
Common Checks
|
Symptom |
Check |
|---|---|
|
The Node does not connect over UDP. |
Confirm that the Port is |
|
The Node over UDP shows as disconnected after about 50 seconds. |
hi received no keep-alive from the SNP. Confirm that UDP Port |
|
AudioFlex controls are missing. |
Confirm in the CCSP Interface Documentation section that the SNP publishes them. They depend on the SNP configuration and licensed options. |
Verify the Configuration
Confirm that the Node reports a connected state and that the Parameter Browser shows the SNP tree. Pin a known parameter, change it in the SNP Manager, and confirm that hi shows the new value. Then change a safe parameter from hi and confirm that the SNP Manager shows the same value.