Ross Video openGear Parameter Controllable Device Integration Configuration
Caution
Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.
Configuration Overview
An openGear frame or card connects to hi as one Parameter Control Node. hi first reads the connection properties of the device over HTTP, then opens a JSON OGP control connection and loads the parameters that the device publishes.
|
Configuration |
What hi Sees |
Use When |
|---|---|---|
|
JSON OGP Control |
The parameter tree that the device publishes, with per-parameter read and write access. |
The device offers the JSON variant of OGP. |
Caution
Force Connection asks the device to accept hi even when it has reached its client limit. The device can then disconnect another client, such as a DashBoard session. Leave it at No unless the commissioning plan requires it.
Before You Begin
-
Use Node admin and open Inventory > Nodes. See Manage Nodes.
-
Confirm the license and minimum hi version in Required Configuration.
-
Use DashBoard to confirm that the device is reachable and to check its client limit.
-
Confirm the network access in Network Requirements. hi needs Port
8080and the control Port.
Configure JSON OGP Control
Device Configuration
-
Install the card in a compatible openGear frame and enable network control. Confirm that the device offers the JSON variant of OGP. openGear uses TCP Port
5254for JSON OGP and Port5253for binary OGP. -
Confirm that the device serves its connection-properties file at
http://<device>:8080/connect/connection-props.xml. hi reads only this URL, and does not read the file on Port80. -
Confirm that the device accepts one more control client. A device can refuse a client when it cannot accept more connections.
hi Configuration
-
Add the openGear Parameter Controllable Device integration (manufacturer Ross Video) in Inventory.
-
Enter the device address and the Port. hi defaults to
5254. -
In the Settings group, keep Version at its default or enter the DashBoard build that the commissioning plan names.
-
Leave Force Connection at
Nounless the device must accept hi at its client limit. -
Create the Node and wait for hi to load the parameters.
-
Open the Parameters tab, select the parameters that hi must monitor, and select Pin Selected. hi polls pinned parameters every 5 seconds.
Settings Summary
|
Setting |
Device Side |
hi Side |
|---|---|---|
|
Control Port |
JSON OGP Port
|
Port
|
|
Connection properties |
File served on HTTP Port |
Read by hi on Port |
|
Client limit |
Number of control clients the device accepts |
Force Connection
|
Common Checks
|
Symptom |
Check |
|---|---|
|
The Node does not connect. |
Confirm that hi reaches the device on Port |
|
The Node connects, then another client disconnects. |
Force Connection is |
|
A parameter cannot be changed. |
The device marks the parameter as read-only. hi shows it as read-only. |
Verify the Configuration