Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.

Minimum hi Version: v2.1.0

Overview

The Evertz® Quartz integration reads Source and Destination names, monitors Crosspoint state, and sets Crosspoints over TCP.

Network Requirements

  • Allow outbound TCP from hi to the Quartz controller. The integration defaults to Port 4000; use the Port commissioned on the controller when it differs.

  • No callback or inbound connection to hi is used.

  • Keep the plaintext control connection on a trusted management network.

Standards Conformance

Standard

Conformance

Notes

Evertz Quartz

Source and Destination names
state reads
and Crosspoint routing

Vendor protocol
no public-standards conformance claimed

Operator Workflow

  • UI Surface in hi: Routing Matrix, Inventory, and Hardware Panel workflows

  • Capabilities: Source/Destination names, Crosspoint reads, Destination interrogation, and Crosspoint setting

  • Routing Semantics: The configured router Sources and Destinations appear in hi routing workflows.

  • Notes for Operators Familiar with the Vendor's Own Tooling: Use vendor tooling for salvos, locks, protection, engineering configuration, and firmware management.

Connection Details

Property

Value

Protocol

Evertz Quartz

Transport

TCP

Default Port

4000 (integration default
device-configurable)

Authentication

No credentials are configured in hi for this connection

Encryption in Transit

Not provided by the configured TCP connection

Connection Model

Persistent TCP command/response with state reads

Required License

hiBase

Traffic Flow

Outbound from hi

Required Configuration

Parameter

Description

Default

Host / IP Address

IP address of the Evertz router controller

-

Port

Quartz TCP control port

4000

Device-Side Setup

Follow Evertz EQX/EQT Quartz Router Controller Integration Configuration for the device-side and hi-side configuration steps.

Supported Features

Feature

Access

Exposed Operation and Scope

Source and Destination Names

Read-only

Read configured names.

Crosspoint State

Read-only

Read all Crosspoints or interrogate a Destination.

Crosspoint Set

Write-only

Route a Source to a Destination on a supported level.

Device Coverage

Tested With identifies devices that have been tested with hi. Potentially Compatible (Not Yet Verified) identifies compatibility candidates that use the same protocol or connection method. Device-specific configuration, firmware, and feature support can affect results.

This integration supports the Evertz Quartz range.

Tested With

  • Evertz EQX

  • Evertz MAGNUM

Supported Product Range

These Evertz routers and controllers support the Quartz protocol:

  • Evertz EQT

  • Evertz Xenon

  • Evertz Q256

  • Evertz Topaz

  • Evertz SC-1000

Potentially Compatible (Not Yet Verified)

  • Other router controllers that expose the same Quartz Source, Destination, and Crosspoint commands.

Known Limitations

  • Validate the matrix dimensions and the level mapping with the installed firmware during commissioning.

  • The controller ends all connections when a new configuration is downloaded to it. Expect the connection to drop and reconnect after an engineering configuration change.

  • A frame with redundant controllers has one IP address per controller, and only the active controller accepts a connection. Use the address of the active controller when you commission hi. hi connects to one controller address and does not fail over. After a changeover, the Node stays disconnected until you change its address to the newly active controller.

  • Quartz command support differs by product and software version. Validate Source and Destination names and Crosspoint reads against your controller during commissioning.

  • The Quartz protocol addresses router levels with letters. Systems use 8 or 16 levels, and MAGNUM-based control systems use up to 26 levels, so check the level mapping against the controller database.

What's Not Supported

  • Salvo execution, Destination locks, and protection operations.

  • Firmware updates and engineering-level configuration remain in the vendor tooling.

  • Failing over between the two controllers of a redundant frame.