hi human interface®
English

Imagine Communications LRC Compatible Router

Imagine Communications LRC Compatible Router

Driver Maturity

Production

Recommended for normal production use.

Caution

Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.

Minimum hi Version: v2.8.0

Information

hi 2.8.0 reintroduced LRC for installations where LRC+ does not perform as expected with some devices. Use LRC+ wherever possible.

Overview

The Imagine Communications® LRC integration reads Source and Destination counts and names, synchronizes Crosspoint state, and sets routes over TCP.

Network Requirements

  • Allow outbound TCP from hi to the LRC controller on Port 52116 by default.

  • No callback or inbound connection to hi is used.

  • Keep the plaintext control connection on a trusted management network.

Standards Conformance

Standard

Conformance

Notes

Imagine LRC

Implemented

Vendor protocol
no public-standards conformance claimed

Operator Workflow

  • UI Surface in hi: Routing Matrix, Inventory, and Hardware Panel workflows

  • Capabilities: Source/Destination discovery and names, Crosspoint synchronization, and Crosspoint setting

  • Routing Semantics: The configured router Sources and Destinations appear in hi routing workflows.

  • Notes for Operators Familiar with the Vendor's Own Tooling: Use vendor tooling for salvos, locks, protection, presets, engineering configuration, and firmware management.

Connection Details

Property

Value

Protocol

Imagine LRC

Transport

TCP

Default Port

52116

Authentication

No credentials are configured in hi for this connection

Encryption in Transit

Not provided by the configured TCP connection

Connection Model

Persistent TCP with Crosspoint state synchronization

Required License

hiBase

Traffic Flow

Outbound from hi

Required Configuration

Parameter

Description

Default

Host / IP Address

IP address of the Imagine router controller

-

Port

LRC TCP control port

52116

Signal Type

Signal type of the controlled matrix
set at creation

Video

Input Count

Number of router inputs
set at creation

16

Output Count

Number of router outputs
set at creation

16

Device-Side Setup

Follow Imagine Communications LRC Compatible Router Integration Configuration for the device-side and hi-side configuration steps.

Supported Features

Feature

Access

Exposed Operation and Scope

Source and Destination Discovery

Read-only

Read Source/Destination counts and names.

Crosspoint State

Read-only

Read current Crosspoints.

Crosspoint Set

Write-only

Route a Source to a Destination.

Database Change Notifications

Read-only updates

When the server reports a change to the logical database, reinitialize and reload the Source and Destination names and the Crosspoints.

Device Coverage

Tested With identifies devices that have been tested with hi. Potentially Compatible (Not Yet Verified) identifies compatibility candidates that use the same protocol or connection method. Device-specific configuration, firmware, and feature support can affect results.

Tested With

  • Imagine Communications Platinum IP3

  • Imagine Communications Magellan SDNO

Potentially Compatible (Not Yet Verified)

  • Imagine Communications routing systems that expose the supported LRC control surface.

  • Other Imagine Platinum frames that host LRC.

Known Limitations

  • LRC Plus channel/level routing is documented separately on the LRC Plus integration page.

  • LRC reports status in an event-driven way. Do not poll continuously, because extra updates slow switch requests and status delivery. Use a closed network dedicated to router control where possible.

  • LRC protocol version 1.1 has no Source disconnect command.

  • Platinum and Magellan SDNO systems provide the LRC interface. Availability of the LRC socket interface depends on the device, so confirm the interface on your product before commissioning.

  • hi creates the first Input Count and Output Count Ports with the Signal Type chosen at creation. For a Port that the router reports above these counts, hi sets the format from the channel name: Level 0 or Video gives a video Port, Level 1 or Audio gives an audio Port, Level 2 or Data gives a data Port, and any other name gives a video Port. hi does not change the format of existing Ports, and it shows a Crosspoint only when the Source and Destination formats match.

  • hi connects to one controller address and does not fail over to a second controller.

  • Validate the counts, names, and routing with the installed firmware during commissioning.

What's Not Supported

  • Salvos, locks, protection, presets, disconnect commands, and raw-message actions.

  • Firmware updates and engineering-level configuration remain in the vendor tooling.

  • Crosspoint error status (XPOINTERR), which only Magellan SDNO provides.

  • Crosspoint buffer control (XBUFFER) and protocol version queries (PROTOCOL).

Trademarks

Note

Imagine Communications is a trademark of Imagine Communications Corp.

RIEDEL Communications is not affiliated with, endorsed by, or officially partnered with Imagine Communications unless explicitly stated.