hi human interface®
English

hiPush Mark 3

hiPush Mark 3

The hiPush Mark 3 family is a range of LCD-button Hardware Panels for the hi system. Every Mark 3 button carries an individually driven 64 x 32 pixel LCD display, so button labels, colors, and Tally state update live from the hi server. Every panel requires the hiGlue license and consumes one hiUser session per connected panel.

Product Security Information

Review intended use and residual risks in Risk Context.

hiPush Model Selection

The right model depends on three factors: how many buttons the operator position needs, the form factor of the rack or desk it occupies, and the panel's power source.

Model

Buttons

Encoders

Form factor

Power

Weight

Lifecycle status

Typical installation

hiPush18 (Mark 3)

18

2

19" 1RU

External PSU (12 V DC)

1020 g

Current

Compact rack-mounted operator surface.

hiPush20 (Mark 3)

20

0

19" 1RU

External PSU (12 V DC)

1010 g

Current

Buttons-only panel for dedicated actions; no encoders.

hiPush32-D (Mark 3)

32

2

Desktop

PoE (802.3af)

1095 g

Current

Operator desk position with a single-cable installation.

hiPush32-S (Mark 3)

32

2

Half-19" 2RU

External PSU (12 V DC)

1095 g

Current

Half-rack mounting, for example, a shading position next to a rasterizer.

hiPush36 (Mark 3)

36

2

19" 1RU

External PSU (12 V DC)

1095 g

Current

Full-width rack-mounted operator surface.

hiPush54 (Mark 3)

54

2

19" 2RU

External PSU (12 V DC)

1630 g

Current

Highest button count in the range; large operator positions.

Decision Shortcuts

  • PoE installation needed? Only the hiPush32-D ships PoE-powered. Every other variant requires the external hiPSU (ordered separately).

  • Desktop, not rack? Either hiPush32-D (PoE) or hiDot (compact, single-knob).

  • Half-rack slot? hiPush32-S is the only half-19" variant; the rest are either full 19" or desktop.

  • Buttons-only, no encoders? hiPush20 is the only variant without encoders.

  • Maximum buttons in a single panel? hiPush54 at 54 buttons + 2 encoders.

What Is the Same Across the Mark 3 Range

Property

All hiPush Mark 3 panels

Button display

64 x 32 pixel LCD per button

Switch operating force

1.7 ± 0.5 N

Network connection

RJ45, 100Base-T Ethernet

Operating temperature

10 °C to +35 °C

Storage temperature

-10 °C to +50 °C

Protection class

IP20

Conformity

CE
RoHS (EN IEC 63000:2018)

Regional Declarations

European Union (CE)
United States (FCC Part 15B SDoC)
Australia (ACMA SDoC)
New Zealand (subject to the Australia–New Zealand mutual-recognition conditions)

CB Safety Certification

hiPush18/20/36/54 and hiPush32-S: IECEE CB Certificate SE-118960 (IEC 62368-1:2023)
hiPush32-D: IECEE CB Certificate SE-119797 (IEC 62368-1:2023)

EMC

hiPush18/20/36/54:
EN 61000-3-2:2019
EN 61000-3-3:2013+A1:2019
EN 55035:2017
EN 55032:2015
hiPush32-S/D:
EN 55032:2022
EN 55035/A11:2022

License requirement

hiGlue + one hiUser per panel

Commissioning and Disposal

For IP address configuration, power-connector pinout, and disposal/WEEE information, see Hardware Commissioning.