Sony HDC Series
Production
Recommended for normal production use.
Caution
Compatibility Note: This information is a general guide and may be incomplete, may not match a specific project implementation, and is subject to change as supported products and versions evolve. Confirm the exact implementation and requirements for each project with Riedel and the relevant equipment vendor, then validate the required functions end to end in the target environment before deployment.
Confirm that the template's Ports and fixed Signal Paths match the commissioned camera configuration.
Minimum hi Version: v2.0.0
Overview
The Sony® HDC Series template represents camera endpoints in the hi Topology. It does not establish a direct control connection to the camera.
Network Requirements
-
No network connection, device address, Port, authentication, or firewall rule is required by this template.
Operator Workflow
-
UI Surface in hi: Inventory, Topology, and routing workflows that use the configured camera endpoints
-
Configuration: Add the Node from the Sony HDC Series template, name its Ports, assign Tags, and connect its outputs to the commissioned Topology
-
Device Control: Use a separately supported CCU, RCP, MSU, or CNA-2 integration when camera Parameter Control is required
Connection Details
|
Property |
Value |
|---|---|
|
Protocol |
Static camera endpoints |
|
Connection Model |
No direct device connection |
|
Required License |
hiBase |
Required Configuration
-
Add a Node from the Sony HDC Series template.
-
Set Count and Start numbering with, both
1by default. These are creation-time settings. -
Name the camera Ports and connect them to the commissioned Topology.
-
Assign Tags needed by the site's routing workflows.
-
Verify that the expected static endpoints and Signal Paths appear in the Topology.
Device-Side Setup
No device-side network setup is required because this template does not connect to the camera.
Supported Features
|
Feature |
Access |
Exposed Operation and Scope |
|---|---|---|
|
Static Camera Endpoints |
Model-only |
Represent configured signal endpoints in hi; no physical-camera read or write occurs. |
|
Camera Ports |
Model-only |
Inputs: CAM, Mic 1, and Mic 2. Outputs: Camera Out, SDI OUT 1, SDI OUT 2, Monitoring, Mic 1 Out, and Mic 2 Out. |
|
Fixed Crosspoints |
Model-only |
CAM to Camera Out, SDI OUT 1, SDI OUT 2, and Monitoring; Mic 1 to Mic 1 Out; Mic 2 to Mic 2 Out. |
Device Coverage
This integration models HDC Series cameras in the Topology only. Because hi does not connect to the camera, it has no Tested With list and no camera firmware range.
Known Limitations
-
This template defines static signal topology only; hi does not connect to the physical camera or expose its live state.
What's Not Supported
-
This template provides static signal endpoints only. Direct camera Parameter Control, Tally control, Sony CNA-2 communication, and webhook events are not supported through it. Use a separately supported CCU, RCP, MSU, or CNA-2 integration for camera Parameter Control.
-
Firmware updates, camera calibration, and device configuration backup.
Trademarks
Note
Sony is a trademark of Sony Group Corporation.
All product names, logos, and brands are property of their respective owners. Copyright in third-party software and materials remains with the respective owners. Use of these names does not imply endorsement.
RIEDEL Communications is not affiliated with, endorsed by, or officially partnered with Sony unless explicitly stated.